Custom Solar Panels & PV Modules
CALLSUN offers custom PV modules for RVs, vehicle rooftops, balconies, off-grid equipment and other installations with specific space or integration requirements. Explore our existing models or discuss a custom size solar panel based on your available space, target output, structure and connection requirements.
Custom specifications are subject to feasibility review.
Anti-shading TwinCell design keeps output stable under partial shade from trees, roof racks and uneven sunlight — a good fit for RV rooftops, vans and vehicle-mounted installations.
- DIMENSIONS
- 1180 × 770 × 35 mm
- WEIGHT
- 9.5 kg
- OPERATING POINT
- Vmp 22.35 V · Imp 8.05 A
- OPEN / SHORT CIRCUIT
- Voc 25.82 V · Isc 8.86 A
- DESIGN
- Compact Footprint · Anti Shade Design · Bifacial Energy Gain
Ultra-compact 200W with higher watt density per square metre for balcony PV, small off-grid gear and space-constrained rooftop setups where every watt per square metre counts.
- DIMENSIONS
- 1304 × 770 × 35 mm
- WEIGHT
- 10.5 kg
- OPERATING POINT
- Vmp 24.83 V · Imp 8.05 A
- OPEN / SHORT CIRCUIT
- Voc 28.68 V · Isc 8.86 A
- DESIGN
- High Temperature Performance · Bifacial Energy Gain · Long Term Power Output
Dual-module parallel circuitry with 1/4-cut cells tuned for 24V systems — purpose-built for RV, marine, off-grid cabins and solar generator applications where partial shade is common and reliable 24V output is critical.
- DIMENSIONS
- 1376 × 766 × 35 mm
- WEIGHT
- 11.3 kg
- OPERATING POINT
- Vmp 34.2 V · Imp 6.1 A
- OPEN / SHORT CIRCUIT
- Voc 40.3 V · Isc 6.5 A
- DESIGN
- High Voltage Output · 12V and 24V Compatibility · Anti Shade Design
4-zone anti-shading design tuned for 12 V systems and off-grid equipment where partial shade would otherwise hit output hard — well suited to vehicle and marine PV.
- DIMENSIONS
- 1422 × 766 × 35 mm
- WEIGHT
- 11.5 kg
- OPERATING POINT
- Vmp 17.30 V · Imp 12.43 A
- OPEN / SHORT CIRCUIT
- Voc 20.09 V · Isc 12.98 A
- DESIGN
- 4 Module Anti Shade Design · 12V System Compatibility · Bifacial Energy Gain
Discuss Your Module Requirements
Custom module development starts with the requirements of the installation. The following details help CALLSUN assess a suitable approach.
Available Space & Dimensions
Share the usable installation area and preferred module dimensions, including any layout or clearance constraints.
Target Output & Electrical Requirements
Provide the target power and any voltage or current requirements. If the module will connect to an existing system, include the relevant equipment specifications.
Structure & Installation
Describe the intended application, mounting arrangement and any structural or installation constraints.
Connections & Interfaces
Share the required cable arrangement, connector details and equipment interfaces, where known.
Available options depend on the combined dimensional, electrical and structural requirements of the project.
From Requirement Review to Production
Based on the project requirements, CALLSUN can support solution assessment, sample trials and production validation. The scope and next steps are confirmed after reviewing the proposed specifications.
Requirement Review
Review the available space, target output, structure and connection requirements.
Sample Trials
Where appropriate, use sample trials to assess the proposed module configuration.
Production Validation
Review the agreed specifications and relevant validation requirements before proceeding with volume production.
Applications with Specific Fit Requirements
Custom modules may be considered where available space, equipment interfaces or installation conditions make standard module formats less suitable.
RVs & Vehicle Rooftops
For layouts where usable roof space and existing rooftop equipment affect module selection.
Balconies & Walls
For installations with specific dimensional, mounting and connection requirements.
Off-Grid Equipment
For equipment applications that require the module to fit a defined space and electrical configuration.
Other Space-Constrained Installations
For projects where module dimensions and integration requirements need to be considered together.
Manufacturing & Quality Control
CALLSUN combines semi-automated production with manual operations for custom glass modules, with production arrangements based on module dimensions and structural requirements.
Relevant documentation and validation requirements should be confirmed for the selected module or proposed configuration.
- EL Inspection
- I-V Testing
- Visual Checks
- Electrical Safety Checks
Custom Solar Panel FAQs
Yes. CALLSUN can assess custom module requirements based on the available space, target output, structure and interfaces. The proposed specifications are subject to feasibility review.
Not necessarily. Start by comparing the listed models with your dimensional and electrical requirements. An existing model may be suitable without further customization.
Please share the application, available space or target dimensions, power and electrical requirements, connection details, estimated quantity and destination. Drawings or equipment specifications can help where available.
The displayed models represent the current range on this page. Requirements outside these models can be discussed with CALLSUN and are subject to feasibility review.
Sample trials can be discussed as part of the project review. Specifications, availability, costs and timing are confirmed for the individual request.
These depend on the module configuration, development requirements and order quantity. Contact CALLSUN with your project details for confirmation.
Certification coverage must be checked for the exact model and configuration. Please confirm the applicable documentation and any additional requirements with CALLSUN.
PRODUCT INQUIRY
Discuss Your Custom Module Requirements
Tell us about your application, available space and target output. Include any electrical, structural or connection requirements so we can review your request.
WhatsApp Scan to chat with us